| Wind Turbines |
|
Battery Charging Wind Generators Soma 1000BC and Soma 400BC
The 1000W and 400W Battery Charging Soma Wind Generators are made to match the battery voltage. A controller is connected between the wind generator and the battery. It performs the functions of rectifying the incoming 3 phase AC power from the wind generator, plus diverting any excess power to the built-in dump load. The power diversion is achieved using PWM transistor circuitry. The battery voltage at which diversion occurs is set using the front panel voltage selection control knob.
Where the wind generator is a long distance from the batteries, a transformer is used at the batteries. This allows the use of a 110V Soma wind generator so that cable size between the wind generator and transformer, located near the batteries, is minimized.

| SPECIFICATIONS – S0MA BATTERY CHARGING WIND GENERATORS | ||
| PARAMETER | SOMA 400BC | SOMA 1000BC |
| Rated Output at 10m/s wind speed | 400W | 1000W |
| Peak Output | 500W | 1200W |
| Cut-in Wind Speed | 4m/s | 3.5m/s |
| Max Design Wind Speed | 50m/s | 50m/s |
| Feathering Mechanism | Tilt up | Tilt up |
| Blade Diameter | 2m | 2.7m |
| Number of Blades | 2 | 2 |
| Operating Speed | 300-1200rpm | 300-800rpm |
| Blade Construction | GRP hollow moulded fibreglass | |
| Alternator Type | Permanent magnet 3 phase AC | |
| Voltage | 12, 24, 32, 48, 110 or 120V | 24, 32, 36, 48, 110 or 120V |
| Regulation | DC PWM into air resistor, adjustable voltage level | |
| Shipping Weight / Volume | 48kg / 0.18m3 | 50kg / 0.18m3 |